Muncy Machine and Upson-Walton

FI-127 Indicator


Part Number: 49056-1123


Dillon FI-127 Indicator Photo

The Dillon FI-127 can store captured data as well as peak and first peak values in its internal database. Operators can track stored data using date/time information and a 6-digit ID number. The stored data can then be printed or sent to a PC or other device using programmable print and data output formats. The FI-127’s seven logic level inputs and the bi-directional serial port can receive control commands from external devices. The instrument can control external devices via any of the three standard cutoff outputs.



Specifications

  • Tension capacities:
    10,000 lb/45 kN/4500 kg.
  • Wire sizes: 3/16 inch through 3/4 inch.
  • Accuracy: ±3% of full scale. Calibrated to specific wire rope size and type.
    ±5% with the same wire rope diameter as calibrated but different wire rope type.
  • Number of calibrations: 3 factory installed wire rope sizes:
    1/2” – 8 x 19
    9/16” – 8 x 19
    5/6” – 8 x 19
    Up to 5 additional wire rope types can be stored independently.
  • Operating range: -4°F to 140°F (-20°C to 60°C)
  • Loading error: Cable elongation of only 0.08 inch (2mm)
  • Display: Dot-graphic LCD display supports full text and 1 inch high digits.
  • Environment protection: Suitable for continued outdoor use.
  • Tension units of measure: pound-force, kilogram force, Newtons.
  • Resolution: configurable low/med/high.
  • Recalibration: At user discretion. Commonly 24 months but should be more frequently with heavy use. Factory recalibrations conducted typically in 2-4 days. On-site recalibration may be possible through your Dillon distributor.
  • Approvals: CE
>